Autoclave 18 Liters Class B with USB Green - My Podologie
Autoclave 18 Liters Class B with USB Green - My Podologie
Autoclave 18 Liters Class B with USB Green - My Podologie
    Autoclave 18 Liters Class B with USB Green - My Podologie
    Autoclave 18 Liters Class B with USB Green - My Podologie
    Autoclave 18 Liters Class B with USB Green - My Podologie
Autoclave 18 Liters Class B with USB Green - My Podologie
Autoclave 18 Liters Class B with USB Green - My Podologie
Autoclave 18 Liters Class B with USB Green - My Podologie
Autoclave 18 Liters Class B with USB Green - My Podologie
Autoclave 18 Liters Class B with USB Green - My Podologie
Autoclave 18 Liters Class B with USB Green - My Podologie
    Autoclave 18 Liters Class B with USB Green - My Podologie
    Autoclave 18 Liters Class B with USB Green - My Podologie
    Autoclave 18 Liters Class B with USB Green - My Podologie
Autoclave 18 Liters Class B with USB Green - My Podologie
Autoclave 18 Liters Class B with USB Green - My Podologie
Autoclave 18 Liters Class B with USB Green - My Podologie

Product information

Description

Green 18-liter Class B autoclave with USB

Warranty details

Safety
- The cycle does not start if the door is not properly closed.
- The automated safety system with a double hydraulic locking device prevents the door from opening while the chamber is under pressure.
- Safety valves prevent pressure buildup in the pressure generator and the camera.
- A safety thermostat prevents overheating in the chamber and the generator
- An automatic safety lock prevents the door from accidentally opening during the sterilization process, and the process protector automatically cuts off the power supply if there is a short circuit or if the power supply is unstable.
- A failure alarm indicates a cycle failure and the detailed error code.
- A door alarm indicates that the door is not secured.
- A low-water alarm indicates when the water tank is empty or overfilled.


Technical specifications
- Voltage: 220-240 VAC; 50/60 Hz; 10A
- Chamber dimensions: 247 x 350 mm
- Tray size: 192 x 285 mm
- Circuit breaker: F16A / 400 V
- 2000 W
- Rated power: 1500 VA
- Sterilization temperature: 121 °C / 134 °C
- Distilled water tank capacity: 2.5 L
- Operating temperature: 5 °C / 40
- Relative humidity: Max. 80%, non-condensing
- External dimensions: 490 x 455 x 600 mm
- Net weight: 47 kg
- Maximum noise level: <70 dB
- Atmospheric pressure: 76 kPa / 106 kPa

Maintenance and error message guide for your sterilizer

Icanclave autoclave: maintenance and error message guide

Components
- Distilled water tank
- LCD screen
- Control panel
- Main switch
- Key for draining distilled and used water
- USB port
- Safety valve
- Ventilation grille
- Locking system
- Power cable
- Label

Included accessories
- Sterilizer
- USB
- 2 instrument trays
- Tray support
- Handle for removing trays
- Door adjustment tool
- 2 drain hoses
- Door pad
- Instruction manual

Regulations
- 93/42 / EEC Medical devices directive.
- 97/23 / EEC Pressure equipment directive.
- EN 13060 Small steam sterilizers.
- EN 61326, EN 61000 EMC.
- EN 61010-1, UL 61010-1 safety requirements.
- EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for processing medical materials.

Autoclave step-by-step process
1. Open the door, take the tools and accessories located in the sterilization chamber, remove the packaging and clean them.

2. Connect the power cord to a suitable power source.

3. Connect the printer (sold separately).

4. Power on: the main switch is located on the front, at the bottom right of the device. Once turned on, the LCD screen will light up and the basic autoclave operating symbols, such as the door position, water level, sterilization program, date, and time, will light up.

5. Remove the top cover and then fill the distilled water tank. If an audible signal sounds, it means you have exceeded the permitted water level in the tank. Empty the excess water until the alarm stops.

6. Preparing the material to be sterilized: place the instruments on the different trays, and separate them according to their materials. If the instruments are not made of stainless steel, use sterilization pouches. These must not come into contact with each other. Check that all instruments are properly placed so that water does not remain in hollow parts. Do not overload the instrument trays and do not place them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.

7. Select the sterilization program.

8. Start the sterilization cycle.
After selecting the sterilization program, place the instruments on the trays in the chamber using the provided plastic tongs.
Once the instruments are properly placed inside, close the door. Caution: make sure the door is properly closed, otherwise the autoclave will not be able to operate.

9. Start the sterilization program.
Press the power button, the autoclave will start operating for approximately 30-75 minutes.

10. End of the sterilization cycle.
Once the sterilization cycle is complete, the printer (not included) will automatically print the full cycle report.
Once the pressure has dropped back to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.
Caution: Use the plastic tongs to remove the instruments.

IMPORTANT: Do not reuse the wastewater after emptying the tank.

It is important to keep the packaging box in case of after-sales service

Description

Green 18-liter Class B autoclave with USB

Warranty details

Safety
- The cycle does not start if the door is not properly closed.
- The automated safety system with a double hydraulic locking device prevents the door from opening while the chamber is under pressure.
- Safety valves prevent pressure buildup in the pressure generator and the camera.
- A safety thermostat prevents overheating in the chamber and the generator
- An automatic safety lock prevents the door from accidentally opening during the sterilization process, and the process protector automatically cuts off the power supply if there is a short circuit or if the power supply is unstable.
- A failure alarm indicates a cycle failure and the detailed error code.
- A door alarm indicates that the door is not secured.
- A low-water alarm indicates when the water tank is empty or overfilled.


Technical specifications
- Voltage: 220-240 VAC; 50/60 Hz; 10A
- Chamber dimensions: 247 x 350 mm
- Tray size: 192 x 285 mm
- Circuit breaker: F16A / 400 V
- 2000 W
- Rated power: 1500 VA
- Sterilization temperature: 121 °C / 134 °C
- Distilled water tank capacity: 2.5 L
- Operating temperature: 5 °C / 40
- Relative humidity: Max. 80%, non-condensing
- External dimensions: 490 x 455 x 600 mm
- Net weight: 47 kg
- Maximum noise level: <70 dB
- Atmospheric pressure: 76 kPa / 106 kPa

Maintenance and error message guide for your sterilizer

Icanclave autoclave: maintenance and error message guide

Components
- Distilled water tank
- LCD screen
- Control panel
- Main switch
- Key for draining distilled and used water
- USB port
- Safety valve
- Ventilation grille
- Locking system
- Power cable
- Label

Included accessories
- Sterilizer
- USB
- 2 instrument trays
- Tray support
- Handle for removing trays
- Door adjustment tool
- 2 drain hoses
- Door pad
- Instruction manual

Regulations
- 93/42 / EEC Medical devices directive.
- 97/23 / EEC Pressure equipment directive.
- EN 13060 Small steam sterilizers.
- EN 61326, EN 61000 EMC.
- EN 61010-1, UL 61010-1 safety requirements.
- EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for processing medical materials.

Autoclave step-by-step process
1. Open the door, take the tools and accessories located in the sterilization chamber, remove the packaging and clean them.

2. Connect the power cord to a suitable power source.

3. Connect the printer (sold separately).

4. Power on: the main switch is located on the front, at the bottom right of the device. Once turned on, the LCD screen will light up and the basic autoclave operating symbols, such as the door position, water level, sterilization program, date, and time, will light up.

5. Remove the top cover and then fill the distilled water tank. If an audible signal sounds, it means you have exceeded the permitted water level in the tank. Empty the excess water until the alarm stops.

6. Preparing the material to be sterilized: place the instruments on the different trays, and separate them according to their materials. If the instruments are not made of stainless steel, use sterilization pouches. These must not come into contact with each other. Check that all instruments are properly placed so that water does not remain in hollow parts. Do not overload the instrument trays and do not place them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.

7. Select the sterilization program.

8. Start the sterilization cycle.
After selecting the sterilization program, place the instruments on the trays in the chamber using the provided plastic tongs.
Once the instruments are properly placed inside, close the door. Caution: make sure the door is properly closed, otherwise the autoclave will not be able to operate.

9. Start the sterilization program.
Press the power button, the autoclave will start operating for approximately 30-75 minutes.

10. End of the sterilization cycle.
Once the sterilization cycle is complete, the printer (not included) will automatically print the full cycle report.
Once the pressure has dropped back to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.
Caution: Use the plastic tongs to remove the instruments.

IMPORTANT: Do not reuse the wastewater after emptying the tank.

It is important to keep the packaging box in case of after-sales service

Référence : 49.006  |  EAN : 102875847701

Autoclave 18 Liters Class B with USB Green

In short
Class B 18 Litre Green Autoclave with USB backup and double hydraulic locking safety. Delivery on...  Read more
Regular price
2.405,00€
Sale price
2.405,00€
Regular price
3.700,00€
Tax included. Shipping calculated at checkout.
Disponible immédiatement État du stock en temps réel dans notre entrepôt Le stock affiché peut varier légèrement, avec un délai de mise à jour pouvant aller jusqu'à 5 minutes. Ces informations sont données à titre indicatif et non contractuel.
Gagnez 2405 points en achetant ce produit
Secure Payment: Visa, MasterCard, Amex, Apple Pay
Free delivery on orders of €130 or more, including VAT
Delivery to your office, a pick-up point, or your home!
Garantie : 1 year
Mentions particulières : Photos non contractuelles

Discover these similar products